SIGNAL TO NOISE RATIO (S/NR)


(Figure 12) depicts a classroom setting in which the instructors voice signal is determined to be approximately 65 dBA at a distance of 3 feet from the teacher. The background noise level is 45 dBA and assumed to be fairly constant through out the room. The Inverse Square Law teaches us that the sound level of the instructors voice signal will be 59 dBA at a 6-foot distance, 53 dBA at a 12-foot distance and 47 dBA at a 24-foot distance.



A good Signal to Noise Ratio should be not less than +15 dB, that is to say the signal strength should be at least 15 decibels above the background noise level in order to achieve good Speech Intelligibility by the listener. From (Figure 12) it can be seen that beyond a 12-foot distance from the instructor the S/NR is far below what it should be.

In a typical classroom the ambient or background noise level in the unoccupied classroom should not exceed 35 dBA with the HVAC system running.

• Soundproofing Products • Sonex Ceiling & Wall Panels • Sound Control Curtains • Equipment Enclosures • Acoustical Baffles & Banners • Solid Wood & Veneer Acoustical Ceiling & Wall Systems • Professional Audio Acoustics • Vibration & Damping Control Fire Retardant Acoustics • Hearing Protection • Moisture & Impact Resistant Products • Floor Impact Noise Reduction • Sound Absorbers • Noise Barriers • Fabric Wrapped Wall Panels • Acoustical Foam (Egg Crate) Acoustical Sealants & Adhesives • Outdoor Noise Control • Assistive Listening Devices • OSHA, FDA, ADACompliance • On-Site Acoustical Analysis • Acoustical Design & Consulting • Large Inventory • Fast Shipment • No Project too Large or Small • Major Credit Cards Accepted

123 Columbia Court North • Suite 201 • Chaska, MN 55318 • Tel: (952)-448-5300
Fax: (952)-448-2613 • 1-(800)-854-2948 • Email: [email protected]
NOISE CONTROL HELP LINE 1-(800)-854-2948